6
USER INSTRUCTIONS
2.16 From the low setting press the UP (w) button once to
increase the flame setting to medium.
2.17 From the medium setting press the UP (w) button once to
increase the flame setting to high.
YELLOW FLAMES WILL APPEAR WHEN THE FIRE HAS
GAINED SUFFICIENT HEAT - TYPICALLY 10 TO 20 MINUTES.
TOUCH PAD CONTROL NOT WORKING
If the appliance is not operating with the touch pad
control:
2.18 Replace the batteries in the battery pack following Section 4.
2.19 If the appliance still fails to operate consult your installer or
Yeoman dealer.
3. TURNING THE APPLIANCE OFF
REMOTE CONTROL
3.1 To turn the appliance off press the On/Off (�) button once.
TOUCH PAD CONTROL
3.2 To turn the appliance off press the On/Off button once.
IF THE FIRE IS EXTINGUISHED OR GOES OUT IN USE,
WAIT 3 MINUTES BEFORE ATTEMPTING TO RELIGHT
IT. THE CONTROL VALVE HAS AN INTERLOCK DEVICE
AND THEREFORE CANNOT BE LIT UNTIL THE 3
MINUTES HAVE ELAPSED.
4. CLEANING THE YEOMAN CL
IMPORTANT: THE OUTER PANELLING OF THE YEOMAN
CL IS MADE FROM CAST IRON. USE CAUTION WHEN
INSTALLING, REMOVING AND STORING AS THE
COMPONENTS ARE HEAVY AND SHOULD BE HANDLED
CAREFULLY.
4.1 Make sure the fire and surrounds are cool before cleaning.
Use:
– A dry cloth or stainless steel product to clean the
polished plate.
– A damp cloth for the glass.
4.2 All Models
Unscrew the handle from the upper door.
Remove the plinth to access the touchpad and battery box
by lifting the hooks clear of the slots on the front of the
appliance, See Diagram 3.
3
AR2694
4.3 Remove the frame to gain complete access to the control
box and the viewing aperture by lifting the hooks clear of
the slots on the front of the appliance, See Diagram 4.
4
AR2693
4.4 Using screwdriver remove the eight screws securing the
window panel to the appliance, Diagram 5.
Take care to support the glass when removing the screws.
5
AR2697