Yeoman and servicing Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Fogões Yeoman and servicing. Yeoman CL8 Installation & Operating Instructions Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
Yeoman CL
High Output Boiler Stoves
Instructions for Use, Installation & Servicing
For use in GB & IE (Great Britain & Republic of Ireland).
PM963 Issue 2 (January 2014)
IMPORTANT
THE OUTER CASING, FRONT AND GLASS PANEL BECOME EXTREMELY HOT DURING
OPERATION AND WILL RESULT IN SERIOUS INJURY AND BURNS IF TOUCHED. IT IS
THEREFORE RECOMMENDED THAT A FIREGUARD COMPLYING WITH BS 8423:2002 IS
USED IN THE PRESENCE OF YOUNG CHILDREN, THE ELDERLY OR INFIRM.
Do not attempt to burn rubbish in this appliance.
Please read these Instructions carefully before installation or use.
Keep them in a safe place for future reference and when servicing the fire.
The commissioning sheet found on page 3 of these instructions should be completed by the Installer.
Vista de página 0
1 2 3 4 5 6 ... 43 44

Resumo do Conteúdo

Página 1 - Yeoman CL

Yeoman CLHigh Output Boiler StovesInstructions for Use, Installation & ServicingFor use in GB & IE (Great Britain & Republic of Ireland).P

Página 2 - Contents

1012-+Control KnobSetting Indicator5.23 The exact setting of the thermostat and the Manual Air Controls may need slight adjustment by trial and error

Página 3

11User Instructions6.5 Fit the plug supplied into the hole where the riddling mechanism is normally located and secure with bolt and clamp (also s

Página 4 - Getting Started

128.4 Place the ash into an Ash Caddy (Part No. 4227) or other suitable container. 8.5 Check and remove ash as often as required when burning solid

Página 5

13Care & Maintenance13. Chimney Sweeping13.1 To maintain safe and efficient use of the appliance, the chimney/flue must be inspected and swept at

Página 6

14TroubleshootingSymptom Cause SolutionOPERATIONDifficulty starting the fire andkeeping it burning wellLow flue draught Consult your installerWet wood

Página 7

15TroubleshootingSymptom Cause SolutionTHE APPLIANCERapid creosote build-up in the chimney Wet wood (over 20% moisture)Use dry seasoned wood (less tha

Página 8

16Installation ChecklistPlease NoteThis section is intended to give an overview of the product performance and essential information required for inst

Página 9

17Installation Checklist2. Essential InformationGENERALModel:Yeoman CL8Yeoman CL8Nominal Heat Output to RoomWood kW 6.4Solid Fuel kW6.4Nominal Heat Ou

Página 10 - User Instructions

18Installation Checklist5. ClearancesIMPORTANT: INSTALLATION MUST COMPLY WITH CURRENT BUILDING REGULATIONSENSURE THAT SUFFICIENT CLEARANCES ARE PROVID

Página 11

19Installation ChecklistNon-Combustible Materials5.2 All appliances will require some clearance between them and any non-combustible materials to all

Página 12 - Care & Maintenance

2Covering the following models:YM-CL8HBMF1 Yeoman CL - High Output Boiler StovesContentsAppliance Commissioning Checklist ...3User

Página 13

201. General1.1 To make the installation of the appliance easier it is best to remove the internal components before fitting into the builders openin

Página 14 - Troubleshooting

21 Note: When installed correctly the front of the baffle fits over the supports on the inside of the firebox and the back fits over the Secondary Ai

Página 15

226. Removal of the Riddling Mechanism The riddling mechanism can be removed for cleaning to maintain good working condition.To remove the riddling m

Página 16 - Installation Checklist

23Pre-Installation Instructions7. Removal of the Cast Plinth7.1 The Cast Plinth can be removed to aid in the installation or as part of the routine m

Página 17

24Installation Instructions1. Installing the ApplianceEach installation is unique to the property so it is not possible to give details to suit every

Página 18

25Installation Instructions1.8 Place the cast top plate feet down on top of the appliance.1.9 Ensure the cast top is flush with the front and sides

Página 19

26 The Flue must be installed in accordance with manufacturers instructions.Seal Collar with Fire CementSelf tapping screwTeeSize Part No.6" 461

Página 20 - Pre-Installation Instructions

274. Open Vent & Cold Feed System4.1 This system must be fitted with a minimum of 22mm diameter open vent discharging into a heat resisting feed

Página 21

28Installation Instructions11. Sealed (Pressurized) System11.1 Do not fit this appliance to sealed or pressurised systems or an unvented hot water cy

Página 22

29HEATING SYSTEM CONTROLSCONTROLS GENERAL1.1 The controls fitted to the system will provide two functions: — To control the comfort level in the hou

Página 23

3Retailer appliance was purchased from:Name:Address:Telephone number:Essential information - MUST be completed:Date Installed:Model Description:Serial

Página 24 - Installation Instructions

30Commissioning1. Commissioning1.1 To commission: — Replace the internal components. — Check the door alignment and catch operation, adjust if

Página 25

31Certificate Of Compliance Upon completing the installation, the form below must be filled in by your installer to comply with the requirements of H

Página 26

32Maintenance & ServicingFor a complete list of spare parts and accessories contact your Yeoman or call 01392 4740111. Annual Service1.1 Before t

Página 27

333. Removing the Woodburning Tray (if fitted) To maintain safe use of the appliance the Woodburning tray should be removed and cleaned regularly .3.

Página 28

34Maintenance & Servicing4.8 Fix glass sealing rope (B) to the matt black side of the top face, see Diagram 4. .Glass rope sealBBlack face44..9

Página 29

357. Adjusting the Door Catch7.1 To adjust the door catch: —Open the door to gain access to the catch.7.2 Use a 13mm A/F spanner to loosen the half

Página 30 - Commissioning

36Technical AppendixLegal RequirementsBefore installation and/or use of this appliance please read these instructions carefully to ensure that all req

Página 31 - Certificate Of Compliance

37Technical Appendix - Flues1. Flue or Chimney2.1 The flue or chimney system must be in good condition. It must be inspected by a competent person a

Página 32 - Maintenance & Servicing

382. Ventilation2.1 Many older buildings are sufficiently ventilated by natural leakage of air to provide suitable air supply for an appliance of 5kW

Página 33

394. Fitting Appliances On A Boat4.1 If an appliance is to be fitted in a boat it must be done in accordance with the latest edition of BS 8511 (Code

Página 34

4Welcome Congratulations on purchasing your Yeoman CL Boiler, if installed correctly Yeoman hope it will give you many years of warmth and pleasure f

Página 35

40Ref. Description1CAST DOOR2DOOR HANDLE ASSEMBLY3WAVE SPRING 4SPRING 6.1MM O/D X 0.61MM DIAMETER WIRE X 22.2MM LONG5TORSION SPRING6DOOR HANDLE CAM7HI

Página 36 - Technical Appendix

41Due to continual technical improvements please check online at www.yeomanstoves.co.uk for the most up to date parts lists.Basic Spare PartsRIDDLING

Página 37 - Technical Appendix - Flues

421STSERVICEDate of Service:...Next Service Due:...

Página 39

Stovax Ltd, Falcon Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7LFTel: (01392) 474011 Fax: (01392) 219932 E-mail: [email protected]

Página 40 - Basic Spare Parts

5Getting StartedAIR CONTROLSTriple Air Systems Several Yeoman appliances have triple air systems providing cleaner burning, and greater efficiency an

Página 41

61.19 It is also recommended to fit a low limit thermostat on the centralheatingreturnsetat45˚C.Thisthermostatwillturnthepumpoffifther

Página 42 - Service Records

7 Poor quality timber: — Causes low combustion efficiency — Produces harmful condensation — Reduces effectiveness of the airwash and life of the

Página 43

8Base ofbaffleLog Guard8 —Close the door. Do not run with the door slightly open except for initial lighting as this could cause over-firing and dama

Página 44 - HETAS Approval

9 Operate the follow controls manually:Secondary Air Control Always have the Secondary Air Control shut when burning solid fuel to ensure the maximu