Yeoman EXE MIDI PR1145 Manual de Instruções

Consulte online ou descarregue Manual de Instruções para Fogões Yeoman EXE MIDI PR1145. Yeoman EXE MIDI PR1145 Instruction manual [en] [fr] Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 23
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Yeoman Exe Midi
Conventional Flue Coal Effect Stove
With upgradeable control valve
Instructions for Use,
Installation and Servicing
For use in GB, IE (Great Britain and Eire)
PR1145 Issue 1 (July 2010)
IMPORTANT
This product contains a Heat resistant glass panel. This panel should be checked during Installation and at each servicing
interval. If any damage is observed on the front face of the glass panel (scratches, scores, cracks or other surface defects), the
glass panel must be replaced and the appliance must not be used until a replacement is installed. Under no circumstances
should the appliance be used if any damage is observed, the glass panel is removed or broken.
Parts of this appliance will become hot during operation; it is therefore recommended that a suitable guard should be used for
protection of young children, the elderly or infirm.
This appliance is guaranteed for 2 years (subject to the conditions on page 3 of this Instruction manual). The second year of the
guarantee will only be valid if the annual service recommended in this Instruction manual has been completed by a GasSafe
registered engineer, and a copy of the service report is available for inspection by a Gazco engineer.
These Instructions must be left with the appliance for future reference and for consultation when servicing the appliance. Please
make the customer aware of the correct operation of the appliance before leaving these instructions with them.
The commissioning sheet found on Page 3 of this Instruction manual must be completed by the Installer prior to leaving the
premises.
Vista de página 0
1 2 3 4 5 6 ... 22 23

Resumo do Conteúdo

Página 1 - Yeoman Exe Midi

Yeoman Exe MidiConventional Flue Coal Effect StoveWith upgradeable control valveInstructions for Use,Installation and ServicingFor use in GB, IE (Grea

Página 2 - CONTENTS

CABA = 643mmB = 43mmC = 12mmAR060414.2 This appliance must not be installed in a room that contains a bath or shower.4.3 The stove is not suitable f

Página 3 - IMPORTANT NOTICE

112.7 The stove is fitted with the Gazco Flue Sure System, which will act to cut off the gas supply to the appliance in the event of incorrect operat

Página 4 - USER INSTRUCTIONS

123.5 Check the pull of the flue system by applying a lighted smoke pellet to the flue system opening. If there is a definite flow into the chimney,

Página 5

13AR036084.8 Place the log retainer in the two guides as shown in Diagram 9.AR20769 FOR CLARITY, THE FOLLOWING LOG ARRANGEMENT DIAGRAMS DO NOT INCLU

Página 6

14INSTALLATION INSTRUCTIONSCOMMISSIONING1. COMMISSIONING After connecting the gas pipe to the stove:1.1 PURGE THE SUPPLY PIPE to dispel any debris t

Página 7

15IGNITION FUNCTIONAL CHECK 1PILOT WILL NOT LIGHTEnsure there is no debris around the pilot assembly, (e.g. soot, etc.) which could short the spark,

Página 8

16PILOT WILL NOT STAY LIT OR FIRE GOES OUT IN USEEnsure there is no debris around the pilot assembly, e.g. coal, soot etc. which could short the spark

Página 9

172.4 Remove the two screws at the back of the firebox and lift the burner unit clean (see Diagram 3).AR144233. PILOT UNIT3.1 Follow the procedure f

Página 10 - INSTALLATION INSTRUCTIONS

183.3 The pilot unit can now be removed by undoing the two screws (see Diagram 6).AR144563.4 Reassemble in reverse order, do not overtighten. NOTE:

Página 11

196.3 Undo the single screw that secures the left hand side of the control cover (see Diagram 10).10AR09156.4 To release the right hand side of the

Página 12

2CONTENTSCOVERING THE FOLLOWING MODELS:YM-N9171FL / YM-N9171LCYM-P9171FL / YM-P9171LC PAGEAPPLIANCE COMMISSIONING CHECKLIST 3 USER INSTRUCTIONS 4I

Página 13

209. GAZCO FLUE SURE SYSTEM9.1 Open the door and remove the ceramics, placing them carefully to one side. Undo the two screws in the back of the fire

Página 14

21 11. CHANGING BETWEEN GAS TYPES In order to change between gas types it will be necessary to change the following items: - Pilot Unit - Control V

Página 15 - SERVICING INSTRUCTIONS

22SERVICE RECORDS1ST SERVICE 2ND SERVICEDate of Service: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Date of Service: ...

Página 16

A division of Stovax LtdFalcon Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7LFTel: (01392) 474500 Fax: (01392) 219932E-mail: yeoman@s

Página 17

3FLUE CHECK PASS FAIL1. Flue is correct for appliance 2. Flue flow test 3. Spillage test GAS CHECK 1. Gas soundness & let by test2. Standin

Página 18

4USER INSTRUCTIONS1.7 The manufacturer considers the full outer casing of this stove to be a working surface which becomes hot when the stove is lit.

Página 19

52. LIGHTING THE STOVE2.1 The control valve is on the right-hand side at the foot of the stove. It has two controls: —The right-hand knob controls t

Página 20

65. CLEANING THE STOVE Advice on Handling and Disposal of Fire Ceramics5.1 The fuel effect logs and embers in this stove are made from Refractory Ce

Página 21

7HEADING6. FUEL BED ARRANGEMENT6.1 Place the flame baffle onto the burner and push against the rear tray lip (see Diagram 5).AR03595Spacer brackets6.

Página 22 - SERVICE RECORDS

8AR0364116.8 Replace the glass frame using the 6 x frame fixing screws (see Diagram 4) and close door.7. GAZCO FLUE SURE SYSTEM The stove is fitt

Página 23 - A division of Stovax Ltd

9INSTALLATION INSTRUCTIONSTECHNICAL SPECIFICATIONCovering the following models:Yeoman Exe MidiYM-N9171FL / YM-N9171LCYM-P9171FL / YM-P9171LC1 x Stove